STROBIC AIR TRI-STACK

AS/NZS 2243.8:2014 Compliant Manifolded Process Fume Exhaust System

Strobic Air Stack AS/NZS 2243.8 compliant Air Pollution Control

The Strobic Air Tri Stack exhaust system is today’s most cost-effective solution to the problems of industrial air pollution control, re-entrainment and odour control, and specifically to meeting AS/NZS 2243.8, AS 1668.2, ANSI Z9.5, ASHRAE 110, NFPA 45 and applicable ventilation standards. It is suitable for a wide range of applications; from restaurant smoke and odour control, through to critical biomedical or chemical laboratory fume exhaust, as well as industrial or emergency diesel generator fume extraction.

Laboratory and Industrial Exhaust Systems

As well as a state of the art system for new-build installation, Strobic Air Tri Stacks are a cost-saving replacement for the tall exhaust stacks and centrifugal exhaust fans that have conventionally been used in laboratory exhaust systems.

Advantages of upgrading to the Strobic Air Tri Stack include:

  • Low profile design replaces the tall, unsightly stacks of conventional industrial exhaust fans. Many Strobic installations have low visibility from the property line.
  • Prevents re-entrainment, by sending a “jet plume” of diluted exhaust air up to 50m high where odours and other contaminants are dispersed effectively eliminating them from the local environment.
  • Compatible with plenum based heat/cooling recovery systems.
  • Nearly maintenance free operation gives significant cost savings.
  • The TriStack ® Smart System gives variable air volume control, together with automatic fan control to maintain optimum efficiency.
  • Direct drive motors, with extremely long life:
    • Eliminate the need to replace belts, pulleys and other drivetrain components.
    • Reduce energy costs through higher efficiency.
    • Direct drive eliminates vibration.

Whatever your air quality management needs, the Strobic Air Tri Stack will probably have a size, capacity and configuration to suit them. Airepure can supply a bespoke system tailored to virtually any pollution and/or odour abatement application.

Strobic Air Tri Stack installations are fast, aided by the modular design. We supply systems both as new-build installations and as retrofits. Our highly experienced engineering staff, backed by our NATA accreditation, will help you design a certifiable air exhaust installation tailored exactly to the needs of your plant.

Recent changes to AS/NZS Safety in Laboratories Part 8: Fume Cupboards state:

  • Manifolding of fume hoods now permitted
  • Redundant fan required
  • Hood face velocities remain the same
  • Exhaust minimum exit velocities remain the same
  • Mandatory risk assessment of fume cupboard requirements, irrespective of individual or manifolded systems.